If a lithium cell is said to have a capacity of 20 Ah, does that mean all 20 Ah can be used?












7












$begingroup$


Toshiba's SCiB 20 Ah Lithium titanate cell is said to have a nominal capacity of 20 Ah. The cutoff voltages are 1.5 V and 2.7 V. Does this mean that all 20 Ah of charge exist between those two cutoff voltages? Otherwise to get all 20 Ah of charge one would have to completely discharge and thus damage the cell.










share|improve this question









$endgroup$








  • 2




    $begingroup$
    This comment is for people who may find this question while using a search engine. Lead acid batteries in particular should not be discharged to their full rated capacity unless cycle life is not a concern. Typically, a 10 Ah lead acid battery will only be discharged to 50%, meaning that it can only supply 5Ah (if decent cycle life is required or expected). Most other battery types can be cycled for most or all of their rated capacity and still have decent cycle life.
    $endgroup$
    – mkeith
    Mar 21 at 3:45


















7












$begingroup$


Toshiba's SCiB 20 Ah Lithium titanate cell is said to have a nominal capacity of 20 Ah. The cutoff voltages are 1.5 V and 2.7 V. Does this mean that all 20 Ah of charge exist between those two cutoff voltages? Otherwise to get all 20 Ah of charge one would have to completely discharge and thus damage the cell.










share|improve this question









$endgroup$








  • 2




    $begingroup$
    This comment is for people who may find this question while using a search engine. Lead acid batteries in particular should not be discharged to their full rated capacity unless cycle life is not a concern. Typically, a 10 Ah lead acid battery will only be discharged to 50%, meaning that it can only supply 5Ah (if decent cycle life is required or expected). Most other battery types can be cycled for most or all of their rated capacity and still have decent cycle life.
    $endgroup$
    – mkeith
    Mar 21 at 3:45
















7












7








7





$begingroup$


Toshiba's SCiB 20 Ah Lithium titanate cell is said to have a nominal capacity of 20 Ah. The cutoff voltages are 1.5 V and 2.7 V. Does this mean that all 20 Ah of charge exist between those two cutoff voltages? Otherwise to get all 20 Ah of charge one would have to completely discharge and thus damage the cell.










share|improve this question









$endgroup$




Toshiba's SCiB 20 Ah Lithium titanate cell is said to have a nominal capacity of 20 Ah. The cutoff voltages are 1.5 V and 2.7 V. Does this mean that all 20 Ah of charge exist between those two cutoff voltages? Otherwise to get all 20 Ah of charge one would have to completely discharge and thus damage the cell.







power batteries charge lithium






share|improve this question













share|improve this question











share|improve this question




share|improve this question










asked Mar 21 at 1:16









jRRRRjRRRR

384




384








  • 2




    $begingroup$
    This comment is for people who may find this question while using a search engine. Lead acid batteries in particular should not be discharged to their full rated capacity unless cycle life is not a concern. Typically, a 10 Ah lead acid battery will only be discharged to 50%, meaning that it can only supply 5Ah (if decent cycle life is required or expected). Most other battery types can be cycled for most or all of their rated capacity and still have decent cycle life.
    $endgroup$
    – mkeith
    Mar 21 at 3:45
















  • 2




    $begingroup$
    This comment is for people who may find this question while using a search engine. Lead acid batteries in particular should not be discharged to their full rated capacity unless cycle life is not a concern. Typically, a 10 Ah lead acid battery will only be discharged to 50%, meaning that it can only supply 5Ah (if decent cycle life is required or expected). Most other battery types can be cycled for most or all of their rated capacity and still have decent cycle life.
    $endgroup$
    – mkeith
    Mar 21 at 3:45










2




2




$begingroup$
This comment is for people who may find this question while using a search engine. Lead acid batteries in particular should not be discharged to their full rated capacity unless cycle life is not a concern. Typically, a 10 Ah lead acid battery will only be discharged to 50%, meaning that it can only supply 5Ah (if decent cycle life is required or expected). Most other battery types can be cycled for most or all of their rated capacity and still have decent cycle life.
$endgroup$
– mkeith
Mar 21 at 3:45






$begingroup$
This comment is for people who may find this question while using a search engine. Lead acid batteries in particular should not be discharged to their full rated capacity unless cycle life is not a concern. Typically, a 10 Ah lead acid battery will only be discharged to 50%, meaning that it can only supply 5Ah (if decent cycle life is required or expected). Most other battery types can be cycled for most or all of their rated capacity and still have decent cycle life.
$endgroup$
– mkeith
Mar 21 at 3:45












3 Answers
3






active

oldest

votes


















10












$begingroup$

The available capacity of a fully charged battery varies with temperature and discharge rate (and duty cycle if it's not constant). It will tend to decrease with each cycle, and previous fast charging, exposure to temperature extremes or fast discharging may have negative effects over time.



If a reputable manufacturer says it is rated at 20Ah that means that under the specified conditions you can get approximately 20Ah from a new battery before it discharges to the point where further discharge may cause damage. The details of how it behaves should be described in the datasheet and application literature. You may wish, for example, to charge slower than the maximum or discharge only to a higher voltage than the minimum in order to extend the battery life. The latter will, of course, reduce the available capacity.



If you'll forgive an analogy, your question is a bit like asking about a car manufacturer that claims 7 liters per 100km (33.6 miles per US gallon) fuel efficiency and whether that means you'll actually get that efficiency. It depends on a lot of factors, such as your driving habits and the condition of the automobile.






share|improve this answer









$endgroup$









  • 4




    $begingroup$
    "It depends on a lot of factors, such as your driving habits and the condition of the automobile" AND if the manufacturer is straight out lying to you, which happens with automobiles and batteries at about the same rate.
    $endgroup$
    – Christian
    Mar 21 at 9:25



















6












$begingroup$

The available current capacity is listed in the data sheet. This is typically listed as current over time at a specific discharge rate, from fully charged to the dictated cut off voltage.



If the operating voltage range is 2.7V to 1.5V, then the stated available capacity when new should be within that range.






share|improve this answer









$endgroup$





















    4












    $begingroup$

    Batteries still have nonzero voltage when they are completely discharged and can supply no more current. They do not discharge down to zero volts. An empty battery reads higher than 0V. It's not like the fluid level in a gas tank.



    Therefore, all 20Ah are between 1.5V and 2.7V. But even then you can still only use about 80% of that without damaging the battery. If it drains so far that it gets to 1.5V then the battery already is completely discharged (and probably damaged too from being discharged so deeply).






    share|improve this answer











    $endgroup$














      Your Answer





      StackExchange.ifUsing("editor", function () {
      return StackExchange.using("mathjaxEditing", function () {
      StackExchange.MarkdownEditor.creationCallbacks.add(function (editor, postfix) {
      StackExchange.mathjaxEditing.prepareWmdForMathJax(editor, postfix, [["\$", "\$"]]);
      });
      });
      }, "mathjax-editing");

      StackExchange.ifUsing("editor", function () {
      return StackExchange.using("schematics", function () {
      StackExchange.schematics.init();
      });
      }, "cicuitlab");

      StackExchange.ready(function() {
      var channelOptions = {
      tags: "".split(" "),
      id: "135"
      };
      initTagRenderer("".split(" "), "".split(" "), channelOptions);

      StackExchange.using("externalEditor", function() {
      // Have to fire editor after snippets, if snippets enabled
      if (StackExchange.settings.snippets.snippetsEnabled) {
      StackExchange.using("snippets", function() {
      createEditor();
      });
      }
      else {
      createEditor();
      }
      });

      function createEditor() {
      StackExchange.prepareEditor({
      heartbeatType: 'answer',
      autoActivateHeartbeat: false,
      convertImagesToLinks: false,
      noModals: true,
      showLowRepImageUploadWarning: true,
      reputationToPostImages: null,
      bindNavPrevention: true,
      postfix: "",
      imageUploader: {
      brandingHtml: "Powered by u003ca class="icon-imgur-white" href="https://imgur.com/"u003eu003c/au003e",
      contentPolicyHtml: "User contributions licensed under u003ca href="https://creativecommons.org/licenses/by-sa/3.0/"u003ecc by-sa 3.0 with attribution requiredu003c/au003e u003ca href="https://stackoverflow.com/legal/content-policy"u003e(content policy)u003c/au003e",
      allowUrls: true
      },
      onDemand: true,
      discardSelector: ".discard-answer"
      ,immediatelyShowMarkdownHelp:true
      });


      }
      });














      draft saved

      draft discarded


















      StackExchange.ready(
      function () {
      StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2felectronics.stackexchange.com%2fquestions%2f428266%2fif-a-lithium-cell-is-said-to-have-a-capacity-of-20-ah-does-that-mean-all-20-ah%23new-answer', 'question_page');
      }
      );

      Post as a guest















      Required, but never shown

























      3 Answers
      3






      active

      oldest

      votes








      3 Answers
      3






      active

      oldest

      votes









      active

      oldest

      votes






      active

      oldest

      votes









      10












      $begingroup$

      The available capacity of a fully charged battery varies with temperature and discharge rate (and duty cycle if it's not constant). It will tend to decrease with each cycle, and previous fast charging, exposure to temperature extremes or fast discharging may have negative effects over time.



      If a reputable manufacturer says it is rated at 20Ah that means that under the specified conditions you can get approximately 20Ah from a new battery before it discharges to the point where further discharge may cause damage. The details of how it behaves should be described in the datasheet and application literature. You may wish, for example, to charge slower than the maximum or discharge only to a higher voltage than the minimum in order to extend the battery life. The latter will, of course, reduce the available capacity.



      If you'll forgive an analogy, your question is a bit like asking about a car manufacturer that claims 7 liters per 100km (33.6 miles per US gallon) fuel efficiency and whether that means you'll actually get that efficiency. It depends on a lot of factors, such as your driving habits and the condition of the automobile.






      share|improve this answer









      $endgroup$









      • 4




        $begingroup$
        "It depends on a lot of factors, such as your driving habits and the condition of the automobile" AND if the manufacturer is straight out lying to you, which happens with automobiles and batteries at about the same rate.
        $endgroup$
        – Christian
        Mar 21 at 9:25
















      10












      $begingroup$

      The available capacity of a fully charged battery varies with temperature and discharge rate (and duty cycle if it's not constant). It will tend to decrease with each cycle, and previous fast charging, exposure to temperature extremes or fast discharging may have negative effects over time.



      If a reputable manufacturer says it is rated at 20Ah that means that under the specified conditions you can get approximately 20Ah from a new battery before it discharges to the point where further discharge may cause damage. The details of how it behaves should be described in the datasheet and application literature. You may wish, for example, to charge slower than the maximum or discharge only to a higher voltage than the minimum in order to extend the battery life. The latter will, of course, reduce the available capacity.



      If you'll forgive an analogy, your question is a bit like asking about a car manufacturer that claims 7 liters per 100km (33.6 miles per US gallon) fuel efficiency and whether that means you'll actually get that efficiency. It depends on a lot of factors, such as your driving habits and the condition of the automobile.






      share|improve this answer









      $endgroup$









      • 4




        $begingroup$
        "It depends on a lot of factors, such as your driving habits and the condition of the automobile" AND if the manufacturer is straight out lying to you, which happens with automobiles and batteries at about the same rate.
        $endgroup$
        – Christian
        Mar 21 at 9:25














      10












      10








      10





      $begingroup$

      The available capacity of a fully charged battery varies with temperature and discharge rate (and duty cycle if it's not constant). It will tend to decrease with each cycle, and previous fast charging, exposure to temperature extremes or fast discharging may have negative effects over time.



      If a reputable manufacturer says it is rated at 20Ah that means that under the specified conditions you can get approximately 20Ah from a new battery before it discharges to the point where further discharge may cause damage. The details of how it behaves should be described in the datasheet and application literature. You may wish, for example, to charge slower than the maximum or discharge only to a higher voltage than the minimum in order to extend the battery life. The latter will, of course, reduce the available capacity.



      If you'll forgive an analogy, your question is a bit like asking about a car manufacturer that claims 7 liters per 100km (33.6 miles per US gallon) fuel efficiency and whether that means you'll actually get that efficiency. It depends on a lot of factors, such as your driving habits and the condition of the automobile.






      share|improve this answer









      $endgroup$



      The available capacity of a fully charged battery varies with temperature and discharge rate (and duty cycle if it's not constant). It will tend to decrease with each cycle, and previous fast charging, exposure to temperature extremes or fast discharging may have negative effects over time.



      If a reputable manufacturer says it is rated at 20Ah that means that under the specified conditions you can get approximately 20Ah from a new battery before it discharges to the point where further discharge may cause damage. The details of how it behaves should be described in the datasheet and application literature. You may wish, for example, to charge slower than the maximum or discharge only to a higher voltage than the minimum in order to extend the battery life. The latter will, of course, reduce the available capacity.



      If you'll forgive an analogy, your question is a bit like asking about a car manufacturer that claims 7 liters per 100km (33.6 miles per US gallon) fuel efficiency and whether that means you'll actually get that efficiency. It depends on a lot of factors, such as your driving habits and the condition of the automobile.







      share|improve this answer












      share|improve this answer



      share|improve this answer










      answered Mar 21 at 1:40









      Spehro PefhanySpehro Pefhany

      212k5162426




      212k5162426








      • 4




        $begingroup$
        "It depends on a lot of factors, such as your driving habits and the condition of the automobile" AND if the manufacturer is straight out lying to you, which happens with automobiles and batteries at about the same rate.
        $endgroup$
        – Christian
        Mar 21 at 9:25














      • 4




        $begingroup$
        "It depends on a lot of factors, such as your driving habits and the condition of the automobile" AND if the manufacturer is straight out lying to you, which happens with automobiles and batteries at about the same rate.
        $endgroup$
        – Christian
        Mar 21 at 9:25








      4




      4




      $begingroup$
      "It depends on a lot of factors, such as your driving habits and the condition of the automobile" AND if the manufacturer is straight out lying to you, which happens with automobiles and batteries at about the same rate.
      $endgroup$
      – Christian
      Mar 21 at 9:25




      $begingroup$
      "It depends on a lot of factors, such as your driving habits and the condition of the automobile" AND if the manufacturer is straight out lying to you, which happens with automobiles and batteries at about the same rate.
      $endgroup$
      – Christian
      Mar 21 at 9:25













      6












      $begingroup$

      The available current capacity is listed in the data sheet. This is typically listed as current over time at a specific discharge rate, from fully charged to the dictated cut off voltage.



      If the operating voltage range is 2.7V to 1.5V, then the stated available capacity when new should be within that range.






      share|improve this answer









      $endgroup$


















        6












        $begingroup$

        The available current capacity is listed in the data sheet. This is typically listed as current over time at a specific discharge rate, from fully charged to the dictated cut off voltage.



        If the operating voltage range is 2.7V to 1.5V, then the stated available capacity when new should be within that range.






        share|improve this answer









        $endgroup$
















          6












          6








          6





          $begingroup$

          The available current capacity is listed in the data sheet. This is typically listed as current over time at a specific discharge rate, from fully charged to the dictated cut off voltage.



          If the operating voltage range is 2.7V to 1.5V, then the stated available capacity when new should be within that range.






          share|improve this answer









          $endgroup$



          The available current capacity is listed in the data sheet. This is typically listed as current over time at a specific discharge rate, from fully charged to the dictated cut off voltage.



          If the operating voltage range is 2.7V to 1.5V, then the stated available capacity when new should be within that range.







          share|improve this answer












          share|improve this answer



          share|improve this answer










          answered Mar 21 at 1:27









          PasserbyPasserby

          57.7k453152




          57.7k453152























              4












              $begingroup$

              Batteries still have nonzero voltage when they are completely discharged and can supply no more current. They do not discharge down to zero volts. An empty battery reads higher than 0V. It's not like the fluid level in a gas tank.



              Therefore, all 20Ah are between 1.5V and 2.7V. But even then you can still only use about 80% of that without damaging the battery. If it drains so far that it gets to 1.5V then the battery already is completely discharged (and probably damaged too from being discharged so deeply).






              share|improve this answer











              $endgroup$


















                4












                $begingroup$

                Batteries still have nonzero voltage when they are completely discharged and can supply no more current. They do not discharge down to zero volts. An empty battery reads higher than 0V. It's not like the fluid level in a gas tank.



                Therefore, all 20Ah are between 1.5V and 2.7V. But even then you can still only use about 80% of that without damaging the battery. If it drains so far that it gets to 1.5V then the battery already is completely discharged (and probably damaged too from being discharged so deeply).






                share|improve this answer











                $endgroup$
















                  4












                  4








                  4





                  $begingroup$

                  Batteries still have nonzero voltage when they are completely discharged and can supply no more current. They do not discharge down to zero volts. An empty battery reads higher than 0V. It's not like the fluid level in a gas tank.



                  Therefore, all 20Ah are between 1.5V and 2.7V. But even then you can still only use about 80% of that without damaging the battery. If it drains so far that it gets to 1.5V then the battery already is completely discharged (and probably damaged too from being discharged so deeply).






                  share|improve this answer











                  $endgroup$



                  Batteries still have nonzero voltage when they are completely discharged and can supply no more current. They do not discharge down to zero volts. An empty battery reads higher than 0V. It's not like the fluid level in a gas tank.



                  Therefore, all 20Ah are between 1.5V and 2.7V. But even then you can still only use about 80% of that without damaging the battery. If it drains so far that it gets to 1.5V then the battery already is completely discharged (and probably damaged too from being discharged so deeply).







                  share|improve this answer














                  share|improve this answer



                  share|improve this answer








                  edited Mar 21 at 1:40

























                  answered Mar 21 at 1:33









                  ToorToor

                  1,277210




                  1,277210






























                      draft saved

                      draft discarded




















































                      Thanks for contributing an answer to Electrical Engineering Stack Exchange!


                      • Please be sure to answer the question. Provide details and share your research!

                      But avoid



                      • Asking for help, clarification, or responding to other answers.

                      • Making statements based on opinion; back them up with references or personal experience.


                      Use MathJax to format equations. MathJax reference.


                      To learn more, see our tips on writing great answers.




                      draft saved


                      draft discarded














                      StackExchange.ready(
                      function () {
                      StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2felectronics.stackexchange.com%2fquestions%2f428266%2fif-a-lithium-cell-is-said-to-have-a-capacity-of-20-ah-does-that-mean-all-20-ah%23new-answer', 'question_page');
                      }
                      );

                      Post as a guest















                      Required, but never shown





















































                      Required, but never shown














                      Required, but never shown












                      Required, but never shown







                      Required, but never shown

































                      Required, but never shown














                      Required, but never shown












                      Required, but never shown







                      Required, but never shown







                      Popular posts from this blog

                      How to change which sound is reproduced for terminal bell?

                      Title Spacing in Bjornstrup Chapter, Removing Chapter Number From Contents

                      Can I use Tabulator js library in my java Spring + Thymeleaf project?