How to enable EMERGENCY_PARSER in Marlin firmware?












4














In the documentation of some commands of the Marlin firmware (like M112 - Emergency Stop), it says that the EMERGENCY_PARSER should be enabled to execute them instantaneously.



The thing is, I didn't find any information there of how to enable that EMERGENCY_PARSER or how it works.



Any help will be appreciated.










share|improve this question





























    4














    In the documentation of some commands of the Marlin firmware (like M112 - Emergency Stop), it says that the EMERGENCY_PARSER should be enabled to execute them instantaneously.



    The thing is, I didn't find any information there of how to enable that EMERGENCY_PARSER or how it works.



    Any help will be appreciated.










    share|improve this question



























      4












      4








      4







      In the documentation of some commands of the Marlin firmware (like M112 - Emergency Stop), it says that the EMERGENCY_PARSER should be enabled to execute them instantaneously.



      The thing is, I didn't find any information there of how to enable that EMERGENCY_PARSER or how it works.



      Any help will be appreciated.










      share|improve this question















      In the documentation of some commands of the Marlin firmware (like M112 - Emergency Stop), it says that the EMERGENCY_PARSER should be enabled to execute them instantaneously.



      The thing is, I didn't find any information there of how to enable that EMERGENCY_PARSER or how it works.



      Any help will be appreciated.







      marlin






      share|improve this question















      share|improve this question













      share|improve this question




      share|improve this question








      edited Nov 23 '18 at 13:51









      0scar

      10.1k21244




      10.1k21244










      asked Nov 23 '18 at 13:30









      fsinisi90fsinisi90

      1456




      1456






















          1 Answer
          1






          active

          oldest

          votes


















          4














          The constant EMERGENCY_PARSER is located in the advanced printer configuration file Marlin/Configuration_adv.h:




          // Enable an emergency-command parser to intercept certain commands as they
          // enter the serial receive buffer, so they cannot be blocked.
          // Currently handles M108, M112, M410
          // Does not work on boards using AT90USB (USBCON) processors!
          //#define EMERGENCY_PARSER


          To enable the EMERGENCY_PARSER, you need to remove the // before #define EMERGENCY_PARSER and recompile the sources.



          Normally your printer will execute a command until it is ready to accept a next instruction. Without the EMERGENCY_PARSER set, the printer finishes the instruction that it is executing at the moment, if set, the execution is interrupted and immediately sent and thus not waiting for a clear space in the buffer.






          share|improve this answer























          • Is there a way to know if EMERGENCY_PARSER is set without looking at the printer configuration file (for example, sending a command or checking the first responses when you connect via serial port)? Was this feature added on Marlin 1.1.0?
            – fsinisi90
            Nov 23 '18 at 13:58










          • @fsinisi90 I don't know if you could try that out. You do need to somehow inject the M112 in the midst of operation, usually that is done by the code as an emergency response on certain limit checks, I do not know how to insert that manually from outside.
            – 0scar
            Nov 23 '18 at 14:25










          • Well, I've already tried with M190 (wait for bed temperature) and then M108 and it's not working, but my firmware is Marlin 1.0.3 and I guess the EMERGENCY_PARSER was added on 1.1.0, so I don't even have the possibility to enable it. Anyway, I was looking for a way to check it on any printer from my source code (I'm connecting through pyserial), without human intervention.
            – fsinisi90
            Nov 23 '18 at 14:57













          Your Answer





          StackExchange.ifUsing("editor", function () {
          return StackExchange.using("mathjaxEditing", function () {
          StackExchange.MarkdownEditor.creationCallbacks.add(function (editor, postfix) {
          StackExchange.mathjaxEditing.prepareWmdForMathJax(editor, postfix, [["$", "$"], ["\\(","\\)"]]);
          });
          });
          }, "mathjax-editing");

          StackExchange.ready(function() {
          var channelOptions = {
          tags: "".split(" "),
          id: "640"
          };
          initTagRenderer("".split(" "), "".split(" "), channelOptions);

          StackExchange.using("externalEditor", function() {
          // Have to fire editor after snippets, if snippets enabled
          if (StackExchange.settings.snippets.snippetsEnabled) {
          StackExchange.using("snippets", function() {
          createEditor();
          });
          }
          else {
          createEditor();
          }
          });

          function createEditor() {
          StackExchange.prepareEditor({
          heartbeatType: 'answer',
          autoActivateHeartbeat: false,
          convertImagesToLinks: false,
          noModals: true,
          showLowRepImageUploadWarning: true,
          reputationToPostImages: null,
          bindNavPrevention: true,
          postfix: "",
          imageUploader: {
          brandingHtml: "Powered by u003ca class="icon-imgur-white" href="https://imgur.com/"u003eu003c/au003e",
          contentPolicyHtml: "User contributions licensed under u003ca href="https://creativecommons.org/licenses/by-sa/3.0/"u003ecc by-sa 3.0 with attribution requiredu003c/au003e u003ca href="https://stackoverflow.com/legal/content-policy"u003e(content policy)u003c/au003e",
          allowUrls: true
          },
          noCode: true, onDemand: true,
          discardSelector: ".discard-answer"
          ,immediatelyShowMarkdownHelp:true
          });


          }
          });














          draft saved

          draft discarded


















          StackExchange.ready(
          function () {
          StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2f3dprinting.stackexchange.com%2fquestions%2f7477%2fhow-to-enable-emergency-parser-in-marlin-firmware%23new-answer', 'question_page');
          }
          );

          Post as a guest















          Required, but never shown

























          1 Answer
          1






          active

          oldest

          votes








          1 Answer
          1






          active

          oldest

          votes









          active

          oldest

          votes






          active

          oldest

          votes









          4














          The constant EMERGENCY_PARSER is located in the advanced printer configuration file Marlin/Configuration_adv.h:




          // Enable an emergency-command parser to intercept certain commands as they
          // enter the serial receive buffer, so they cannot be blocked.
          // Currently handles M108, M112, M410
          // Does not work on boards using AT90USB (USBCON) processors!
          //#define EMERGENCY_PARSER


          To enable the EMERGENCY_PARSER, you need to remove the // before #define EMERGENCY_PARSER and recompile the sources.



          Normally your printer will execute a command until it is ready to accept a next instruction. Without the EMERGENCY_PARSER set, the printer finishes the instruction that it is executing at the moment, if set, the execution is interrupted and immediately sent and thus not waiting for a clear space in the buffer.






          share|improve this answer























          • Is there a way to know if EMERGENCY_PARSER is set without looking at the printer configuration file (for example, sending a command or checking the first responses when you connect via serial port)? Was this feature added on Marlin 1.1.0?
            – fsinisi90
            Nov 23 '18 at 13:58










          • @fsinisi90 I don't know if you could try that out. You do need to somehow inject the M112 in the midst of operation, usually that is done by the code as an emergency response on certain limit checks, I do not know how to insert that manually from outside.
            – 0scar
            Nov 23 '18 at 14:25










          • Well, I've already tried with M190 (wait for bed temperature) and then M108 and it's not working, but my firmware is Marlin 1.0.3 and I guess the EMERGENCY_PARSER was added on 1.1.0, so I don't even have the possibility to enable it. Anyway, I was looking for a way to check it on any printer from my source code (I'm connecting through pyserial), without human intervention.
            – fsinisi90
            Nov 23 '18 at 14:57


















          4














          The constant EMERGENCY_PARSER is located in the advanced printer configuration file Marlin/Configuration_adv.h:




          // Enable an emergency-command parser to intercept certain commands as they
          // enter the serial receive buffer, so they cannot be blocked.
          // Currently handles M108, M112, M410
          // Does not work on boards using AT90USB (USBCON) processors!
          //#define EMERGENCY_PARSER


          To enable the EMERGENCY_PARSER, you need to remove the // before #define EMERGENCY_PARSER and recompile the sources.



          Normally your printer will execute a command until it is ready to accept a next instruction. Without the EMERGENCY_PARSER set, the printer finishes the instruction that it is executing at the moment, if set, the execution is interrupted and immediately sent and thus not waiting for a clear space in the buffer.






          share|improve this answer























          • Is there a way to know if EMERGENCY_PARSER is set without looking at the printer configuration file (for example, sending a command or checking the first responses when you connect via serial port)? Was this feature added on Marlin 1.1.0?
            – fsinisi90
            Nov 23 '18 at 13:58










          • @fsinisi90 I don't know if you could try that out. You do need to somehow inject the M112 in the midst of operation, usually that is done by the code as an emergency response on certain limit checks, I do not know how to insert that manually from outside.
            – 0scar
            Nov 23 '18 at 14:25










          • Well, I've already tried with M190 (wait for bed temperature) and then M108 and it's not working, but my firmware is Marlin 1.0.3 and I guess the EMERGENCY_PARSER was added on 1.1.0, so I don't even have the possibility to enable it. Anyway, I was looking for a way to check it on any printer from my source code (I'm connecting through pyserial), without human intervention.
            – fsinisi90
            Nov 23 '18 at 14:57
















          4












          4








          4






          The constant EMERGENCY_PARSER is located in the advanced printer configuration file Marlin/Configuration_adv.h:




          // Enable an emergency-command parser to intercept certain commands as they
          // enter the serial receive buffer, so they cannot be blocked.
          // Currently handles M108, M112, M410
          // Does not work on boards using AT90USB (USBCON) processors!
          //#define EMERGENCY_PARSER


          To enable the EMERGENCY_PARSER, you need to remove the // before #define EMERGENCY_PARSER and recompile the sources.



          Normally your printer will execute a command until it is ready to accept a next instruction. Without the EMERGENCY_PARSER set, the printer finishes the instruction that it is executing at the moment, if set, the execution is interrupted and immediately sent and thus not waiting for a clear space in the buffer.






          share|improve this answer














          The constant EMERGENCY_PARSER is located in the advanced printer configuration file Marlin/Configuration_adv.h:




          // Enable an emergency-command parser to intercept certain commands as they
          // enter the serial receive buffer, so they cannot be blocked.
          // Currently handles M108, M112, M410
          // Does not work on boards using AT90USB (USBCON) processors!
          //#define EMERGENCY_PARSER


          To enable the EMERGENCY_PARSER, you need to remove the // before #define EMERGENCY_PARSER and recompile the sources.



          Normally your printer will execute a command until it is ready to accept a next instruction. Without the EMERGENCY_PARSER set, the printer finishes the instruction that it is executing at the moment, if set, the execution is interrupted and immediately sent and thus not waiting for a clear space in the buffer.







          share|improve this answer














          share|improve this answer



          share|improve this answer








          edited Nov 23 '18 at 13:49

























          answered Nov 23 '18 at 13:44









          0scar0scar

          10.1k21244




          10.1k21244












          • Is there a way to know if EMERGENCY_PARSER is set without looking at the printer configuration file (for example, sending a command or checking the first responses when you connect via serial port)? Was this feature added on Marlin 1.1.0?
            – fsinisi90
            Nov 23 '18 at 13:58










          • @fsinisi90 I don't know if you could try that out. You do need to somehow inject the M112 in the midst of operation, usually that is done by the code as an emergency response on certain limit checks, I do not know how to insert that manually from outside.
            – 0scar
            Nov 23 '18 at 14:25










          • Well, I've already tried with M190 (wait for bed temperature) and then M108 and it's not working, but my firmware is Marlin 1.0.3 and I guess the EMERGENCY_PARSER was added on 1.1.0, so I don't even have the possibility to enable it. Anyway, I was looking for a way to check it on any printer from my source code (I'm connecting through pyserial), without human intervention.
            – fsinisi90
            Nov 23 '18 at 14:57




















          • Is there a way to know if EMERGENCY_PARSER is set without looking at the printer configuration file (for example, sending a command or checking the first responses when you connect via serial port)? Was this feature added on Marlin 1.1.0?
            – fsinisi90
            Nov 23 '18 at 13:58










          • @fsinisi90 I don't know if you could try that out. You do need to somehow inject the M112 in the midst of operation, usually that is done by the code as an emergency response on certain limit checks, I do not know how to insert that manually from outside.
            – 0scar
            Nov 23 '18 at 14:25










          • Well, I've already tried with M190 (wait for bed temperature) and then M108 and it's not working, but my firmware is Marlin 1.0.3 and I guess the EMERGENCY_PARSER was added on 1.1.0, so I don't even have the possibility to enable it. Anyway, I was looking for a way to check it on any printer from my source code (I'm connecting through pyserial), without human intervention.
            – fsinisi90
            Nov 23 '18 at 14:57


















          Is there a way to know if EMERGENCY_PARSER is set without looking at the printer configuration file (for example, sending a command or checking the first responses when you connect via serial port)? Was this feature added on Marlin 1.1.0?
          – fsinisi90
          Nov 23 '18 at 13:58




          Is there a way to know if EMERGENCY_PARSER is set without looking at the printer configuration file (for example, sending a command or checking the first responses when you connect via serial port)? Was this feature added on Marlin 1.1.0?
          – fsinisi90
          Nov 23 '18 at 13:58












          @fsinisi90 I don't know if you could try that out. You do need to somehow inject the M112 in the midst of operation, usually that is done by the code as an emergency response on certain limit checks, I do not know how to insert that manually from outside.
          – 0scar
          Nov 23 '18 at 14:25




          @fsinisi90 I don't know if you could try that out. You do need to somehow inject the M112 in the midst of operation, usually that is done by the code as an emergency response on certain limit checks, I do not know how to insert that manually from outside.
          – 0scar
          Nov 23 '18 at 14:25












          Well, I've already tried with M190 (wait for bed temperature) and then M108 and it's not working, but my firmware is Marlin 1.0.3 and I guess the EMERGENCY_PARSER was added on 1.1.0, so I don't even have the possibility to enable it. Anyway, I was looking for a way to check it on any printer from my source code (I'm connecting through pyserial), without human intervention.
          – fsinisi90
          Nov 23 '18 at 14:57






          Well, I've already tried with M190 (wait for bed temperature) and then M108 and it's not working, but my firmware is Marlin 1.0.3 and I guess the EMERGENCY_PARSER was added on 1.1.0, so I don't even have the possibility to enable it. Anyway, I was looking for a way to check it on any printer from my source code (I'm connecting through pyserial), without human intervention.
          – fsinisi90
          Nov 23 '18 at 14:57




















          draft saved

          draft discarded




















































          Thanks for contributing an answer to 3D Printing Stack Exchange!


          • Please be sure to answer the question. Provide details and share your research!

          But avoid



          • Asking for help, clarification, or responding to other answers.

          • Making statements based on opinion; back them up with references or personal experience.


          Use MathJax to format equations. MathJax reference.


          To learn more, see our tips on writing great answers.




          draft saved


          draft discarded














          StackExchange.ready(
          function () {
          StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2f3dprinting.stackexchange.com%2fquestions%2f7477%2fhow-to-enable-emergency-parser-in-marlin-firmware%23new-answer', 'question_page');
          }
          );

          Post as a guest















          Required, but never shown





















































          Required, but never shown














          Required, but never shown












          Required, but never shown







          Required, but never shown

































          Required, but never shown














          Required, but never shown












          Required, but never shown







          Required, but never shown







          Popular posts from this blog

          How to change which sound is reproduced for terminal bell?

          Can I use Tabulator js library in my java Spring + Thymeleaf project?

          Title Spacing in Bjornstrup Chapter, Removing Chapter Number From Contents